SN54/74LS83A



             FUNCTIONAL DESCRIPTION
               The LS83A adds two 4-bit binary words (A plus B) plus the incoming carry. The binary sum appears on the sum outputs (∑ 1 –∑ 4 )
             and outgoing carry (C 4 ) outputs.

               C 0  + (A 1 +B 1 )+2(A 2 +B 2 )+4(A 3 +B 3 )+8(A 4 +B 4 ) = ∑ 1 +2∑ 2 +4∑ 3 +8∑ 4 +16C 4
               Where: (+) = plus
               Due to the symmetry of the binary add function the LS83A can be used with either all inputs and outputs active HIGH (positive
             logic) or with all inputs and outputs active LOW (negative logic). Note that with active HIGH Inputs, Carry Input can not be left open,
             but must be held LOW when no carry in is intended.

             Example:


                                 C 0  A 1  A 2  A 3  A 4  B 1  B 2  B 3  B 4  ∑ 1  ∑ 2  ∑ 3  ∑ 4  C 4
                  Logic Levels    L   L   H   L   H   H    L   L   H   H   H   L   L     H
                   Active HIGH    0   0   1   0    1  1    0   0   1   1   1   0   0     1   (10+9 = 19)
                   Active LOW     1   1   0   1    0  0    1   1   0   0   0   1   1     0   (carry+5+6 = 12)


               Interchanging inputs of equal weight does not affect the operation, thus C 0 , A 1 , B 1 , can be arbitrarily assigned to pins 10, 11,
             13, etc.





                                                      FUNCTIONAL TRUTH TABLE
                                          C (n–1)     A n       B n      ∑ n        C n
                                            L          L        L         L          L
                                            L          L        H         H          L
                                            L          H        L         H          L
                                            L          H        H         L          H
                                            H          L        L         H          L
                                            H          L        H         L          H
                                            H          H        L         L          H
                                            H          H        H         H          H
                                       C 1  — C 3  are generated internally
                                       C 0  — is an external input
                                       C 4  — is an output generated internally






             GUARANTEED OPERATING RANGES
               Symbol                   Parameter                             Min       Typ      Max      Unit
              V CC      Supply Voltage                               54       4.5       5.0      5.5       V
                                                                     74       4.75      5.0      5.25
              T A       Operating Ambient Temperature Range          54       –55       25       125       °C
                                                                     74        0        25        70

              I OH      Output Current — High                       54, 74                       –0.4      mA
              I OL      Output Current — Low                         54                          4.0       mA
                                                                     74                          8.0







                                                    FAST AND LS TTL DATA
                                                             5-81
                                                                                          www.AirSuplyLab.com